What is a UPS?
Inverter

High Energy Storage
(sufficient for homes)
Slow switchingUPS

Low Energy Storage
(sufficient for Pcs)
Fast switchingOUR UPS
The best of both worlds
We know how important power is for living in today's world, and we also know how to deliver it just right. Su-vastika's UPS provides power backup to your home, office or commercial establishment without any interruption or blackout keeping you comfortable and connected always. The Su-vastika's UPS range is available in a variety of power configurations to meet power backup needs according to your load requirement. Every UPS gone through strict quality control i.e. Automated Testing Zig & come with a robust after-sales support and warranty. Su-vastika's UPS allows us to live an unlimited energy lifestyle.
What does our UPS do?
During power-supply
Stabilizes the power-supply to keep your appliances healthy.
During power-cut
Smartly switches to battery
power and
provides a regulated
power supply.

UPS With a brain
Powered with artificial Intelligence.
LCD Display
Message

Isolation
Transformer
Our UPS have Built-in Isolation Transformer. Isolation also referred to as galvanic isolation, implies that no direct path exists for the current to flow from the source to the load. An isolation transformer provides isolation between the electrical devices and the source powering these devices. In other words, with an isolation transformer, the output power circuit is electrically and physically isolated from the input power circuit. As a result, the isolation transformer provides safety to the users and the appliances.
Read More

Bi-Directional
Technology
Su-vastika’s UPS works on the Revolutionary Bi-directional technology. A bi-directional technology is a technology that allows for two-way charging due to its ability of two-way conversion—from AC to DC and from DC to AC.A bi-directional technology uses the same PWM (Pulse Width Modulation) based, MOSFET (metal–oxide–semiconductor field-effect transistor) circuit to charge and discharge the battery.
Read More

Works in three modes

Regulated
Mains
When Grid supply is available.
Smart
AVR (Automatic Voltage Regulation)
Frequent voltage and frequency fluctuations in households are common occurrences. The moment voltage supply goes down below a certain level, we observe the speed of fans going slow, the blub light dimming, or the tube light blinking frequently. This is called a Low Voltage supply. Also, there are occasions when the voltage jumps high. We all may have observed that as we switch the bulb on, it goes off and gets fused as it cannot withstand a High Voltage spike.


With Smart Automatic Voltage Regulation (AVR) feature or when your mains supply voltage fluctuates (rises or drops beyond the Safe Voltage range), Falcon plus seamlessly switches to the battery power, ensuring a safe power supply to all your appliances.
Safe voltage range
(Brain with a Muscle)
Suppose there is a sudden high voltage spike. Now your home's MCB might not be able to protect your appliances, but your Falcon plus will. It will rapidly switch from the mains to the battery. In fact, Falcon plus can take up to 2.5x its load capacity, supporting your entire load during that high voltage spike. It then intelligently reminds you to turn off the extra appliances, so that the load can be reduced.

Advanced
Protection
Short circuits are very common. Therefore every household is equipped with an MCB or main fuse. However, these can be slow and inefficient at protecting your appliances from damage.
We know how much you love your appliances. Therefore, we have designed Falcon Plus to add a smart layer of protection to them. It has an inbuilt Special MCB, which trips and protects all your appliances even before the traditional MCB can respond.

Charging
Section
There are multiple type of Batteries available in the market which has the advantages and disadvantages and accordingly we charge them based on their characteristics. For example if we have to charge a Tubular Lead Acid battery than we have to take the minimum time of 10 hours before we completely charge it. If we try to charge faster than these Batteries will be short lived and need frequent water topping. If we have to charge the Valve Regulated Lead Acid Batteries which are called sealed Maintenance Free batteries they need to be charged in 6 to 8 hours and if we try to charge them faster than that their life is also reduced. In case of Lithium Batteries we can charge them in 2 to 4 hours and they have a life cycle nearly 5 times than that of Lead Acid Batteries. It's very important how the charger of a UPS is designed to take care of the battery as the life of the battery will majorly dependent on the charger technology.
Our UPS has the charging capacity of 15 Amp which can charge the 150 Ah battery in 10 hours .So the size of the charger is very important to check before buying any UPS. The next parameter is how the charging is done is it flat charging or it's done in stages. In Lead Acid battery charging has to be fast till the 80 percent of the charge but rest 20 percent need little slow charging because the water is hot inside the battery when we are charging it so we need to follow a pattern by which we reduce the heating when we are charging it so that water doesn't evaporate and the more we control the heating inside the battery life of the battery is increased.
Battery Charging Mechanism:
Falcon Plus is built with a Right Charging Mechanism that
charges batteries optimally for longer life

Safe Charging
(Six stage charging)
Most inverters charge the battery in a flat, linear manner. But just like monotony upsets you, monotonous or flat charging deteriorates battery health.
Ideally, 80% of a battery should be fast-charged, while the rest 20% should be charged slowly to avoid over-heating and loss of water-topping. With its Generation Four microprocessor, Falcon Plus carries out charging in six thoughtful stages for maximum efficiency in charging.

Adaptive
Performance
using ATC
Falcon Plus is designed for rough weather conditions. It has an ambient sensor and antenna placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Falcon Plus senses the temperature around it and then makes intelligent adjustments.

For example, in summers or hotter regions, the temperature is high, and hence the battery is charged to a lower voltage for the same power back-up performance. This saves you some extra bucks while also making sure the battery doesn't overheat, lose water, or get damaged. Similarly, in winters or colder places, the temperature is lower and hence the battery is charged to a higher boost voltage to make sure you get the required or expected amount of power back-up. This makes Falcon Plus a perfect choice for any climate, from the extremes of Northern America and Europe to the beating heat in Middle-East and South-East Asia, we are ready for a rough world.
Want to know more about ATC

Low
Requisite
Typically, batteries require a 130V input to charge itself, but this is not available across the world at every time. Regions with frequent outages and low grid voltages may result in poor or no charging.
In such cases, people resort to using stabilizers to get optimum voltage for charging. To ease this, Falcon Plus is equipped with Advanced Circuitry that charges the battery with as low as a 90V input.

Automatic
Bypass
Now, what if your UPS has a technical error, and is unable to switch your load back to the main supply? And imagine this happens in the middle of a summer night, and an electrician can only come the next morning. Intolerable, right?
This is common with almost every UPS or Inverter but not in the Falcon plus models because it has a feature of ‘Automatic bypass system’ which bypasses the Mains supply even when the UPS is faulty.

Rapid
Switching
Intelligently changing between mains and backup.
Fast
Switching
Traditional inverters have higher switching time. This means your appliances will reset during changeover between mains to backup.
Falcon plus is blazingly fast. It automatically detects a power-cut or voltage fluctuation and switches to its backup mode in milliseconds. So you and your appliances won't even get to know there was a power-cut. This means your computer, Wi-Fi, and other critical equipment can run uninterrupted without resetting.
Because who likes to stop?

Battery
/Inverter
Mode
Charging and backup cycles.
The battery sits at the heart of your inverter's power back-up functionality. Charging and Dis-charging cycles define life of a battery, and making both these processes efficient is crucial.
Falcon Plus is built to keep your battery healthy. It is designed for efficient charging and discharging, hence keeping the battery running for longer with reduced upkeep efforts and costs.

Pure Sine
Wave Technology
Many inverters still provide a square wave output which is not healthy for your appliances. Falcon Plus is designed to provide a smooth, continuous sine-wave power output to your appliances just as they require it.
Want to know more about Sine wave technology

Backup
Selection
Every battery is built to accept a certain maximum allowed charging speed. A Tubular Lead-Acid battery needs a minimum of 10 hours, a Sealed Maintenance Free (SMF) battery requires 6-8 hours, while a Lithium-Ion battery requires 2-4 hours to get fully charged in a healthy way.
Charging the batteries faster than these healthy limits reduces the battery's life, and increases maintenance costs and hassles. That's why Falcon Plus is built with the Right Charger that charges batteries at optimum speed.

Battery Selection Switch is an innovative feature of Falcon Plus that enables you to select the battery type you have installed so that it can control and optimize the charging speed to keep your battery healthy. This makes Falcon Plus compatible with diverse battery sizes as per user need for load and backup time
Beware, If a battery is charged faster than its maximum allowed speed, the battery will frequently get overheated, lose water, and will eventually die off prematurely.
Discharging Mechanism:
Letting out energy to your appliances elegantly is a breeze for Falcon Plus. We focus on keeping both your appliances & the battery fine.

Safe
Discharge
With prolonged usage, a battery's life gets reduced. This is what happens to every battery after multiple charge-discharge cycles, even inverter batteries. Nerds call it battery fatigue.
Falcon Plus knows how to beat this problem too. When the battery is being used to power your appliances and is about to get empty (but not fully empty), Falcon Plus places a reserve. This means it doesn't let the battery get fully or deeply discharged, hence extending the life of the battery by leaps and bounds.
This is similar to the reserve tank we have in our cars and scooters. It makes sure that even after you run out of battery power, you are still left with the reserved capacity to get done with emergency situations, by simply pressing a button.

Soft Start
(Gentle to your appliances)
A great beginning makes way for a great journey. Falcon Plus knows this very well. Unlike traditional inverters that allow a sudden inrush of current which can be harmful to your appliances, Falcon Plus goes for a cushioned start-up.
It gradually increases the voltage to let your appliances ease-in. This prevents electrical and mechanical shocks to the sensitive and costly appliances in your house.


Generator
compatible
Many times when the local grid fails, you need to depend on your Domestic Power Generators. Ordinary inverters are incompatible with such ACs due to their high fluctuations. But Falcon plus can normalize and adapt to such fluctuations, making it perfect to pair up with Domestic Generators because our UPS has a frequency bypass range of 42Hz – 55Hz.

Overload & Short
circuit Feature
We have given a special overload feature in which when the ups once get overloaded will give 8 times retry before it shuts down. This feature is very important for the customer as when the costumer put extra load which cannot be supported by the ups then it switch off immediately and keep giving warning. Then customer has to reduce the load and go to the ups and reset the front switch which is very uncomfortable for the costumer because at times the whole house gets into darkness and for the costumer to switch off the load and reaches to the ups is tough as it laying in one corner of the house or office. So we have given a special feature in our ups, in case of overload our ups gives you 8 times switching on and off load, in that timing costumer can reduce the load and there is no sudden darkness in the house/office. Just like overload retries our UPS has a feature of short circuit retries as well.
In this feature whenever there is a short circuit our UPS will shut down automatically and start again. In this process our UPS will check whether the condition of short circuit has been eliminated or not if the short circuit has been eliminated the UPS will start working normally and if condition of short circuit continues then our UPS will retry 4 times before permanently shut down. In order to make it operational again, reset the front switch of UPS.


So now you know why we say Falcon Plus is the smartest thing we've ever made. Well, it's just because when we set out to make a product, we don't aim for beating our competition, we instead aim to push humanity forward.
Technical Specification
MODEL (FALCON +) |
2300VA |
BATTERY VOLTAGE |
24V |
TECHNOLOGY |
LATEST BI-DIRECTIONAL TECHNOLOGY |
MAINS MODE |
|
INPUT VOLTAGE RANGE (WUPS MODE) |
85V-290V |
INPUT VOLTAGE RANGE (UPS MODE) |
185V-265V |
OUTPUT VOLTAGE |
SAME AS INPUT |
CHARGING CURRENT |
15A,20A (USER SELECTABLE) |
FREQUENCY BYPASS RANGE |
42Hz- 55Hz |
CHANGE OVER TIME |
|
UPS MODE |
≤ 8 ms |
WUPS MODE |
≤ 20 ms |
BATTERY MODE |
|
OUTPUT WAVEFORM |
PURE SINE WAVE |
OUTPUT FREQUENCY |
50.0 ± 0.1Hz |
TOTAL HARMONIC DISTORTION (THD) |
<3% |
PROTECTIONS |
|
MAINS MODE: |
|
OVERLOAD/SHORT CIRCUIT |
MAINS MCB WILL TRIP |
BATTERY OVERCHARGE |
BATTERY HIGH CUT |
BATTERY MODE: |
|
OVERLOAD PROTECTION |
YES WITH 8 TIMES AUTO RESET |
SHORT CIRCUIT PROTECTION |
YES WITH 4 TIMES AUTO RESET |
OVER TEMPERATURE PROTECTION |
YES HIGH TEMPERATURE SHUTDOWN |
AUTOMATIC TEMPERATURE COMPENSATION (ATC) |
-10°C to 60°C |
OPERATING TEMPERATURE |
-10°C to 45°C |